FA-TR-01.
What are the Code / Clauses used for Wind Load
Calculations in Build-Master?
Solution:Presently
the program calculates the wind load assuming
uniform wind pressure throughout the height of
the building. Wind load at every floor is calculated
from the projected length of the building at each
level into floor height of that level (Half the
floor height above + Half the floor height below)
into the wind pressure. Values calculated are
printed in .DPA file.
FA-TR-02.
After "Frame Analysis Parameters" option
is selected "Files not updated" window
appears.
Solution: Depending
on the interdependancy of Data files, the Program
checks whether data files at all levels are up
to date in proper sequence. It uses the file Date
and Time to check this interdependancy. At each
level the files shall be generated in the following
sequence : .dxf, .rcc, .arc, .par, .inr, .dat,
.out Hence if any of these files are not updated
in the above sequence, then Program gives this
warning.
FA-TR-03.
The Frame Analysis is terminate at 50% or An error
message appears 'Can not allocate memory'
Solution:
The
reason for this may be the mismatch in column
co-ordinates. To locate the floor at which there
is a mismatch in column co-ordinates. From 'Modify
Project' option of the project menu, modify all
floor names or any of the floor name (say PL).
Then carry out Frame Analysis. Now starting from
lower level, change the floor names one by one
to their original floor names. Carry out Frame
Analysis after changing each floor name. This
way the floor with mismatch can be located easily. |