EP-TR-01. An Error Message appears "This program has performed an illegal operation" while executing commands in Edit Plan Data ?
Solution : If Active-X Components are not registered properly, some options from Edit Plan Data do not run. Run the Register Active-X Components from Utilities Menu.

EP-TR-02. For a slab enclosed by a curved beam, lines indicating Slab distribution(Oneway or Two way) appear slanting. What should I do?
Solution : The lines indicating Slab Distribution are parallel and/or perpendicular to the first part of the curved beam around it. Hence change the first part/parts of the beam, parallel or perpendicular to the desired direction.

EP-TR-03. An Error message appears, "Mismatch in Column Data".
Solution : If the plan is created in CAD and imported in Build-Master, the Default value of Decimal places of accuracy is 16. Hence the Format in .RCC File is changed. Therefore while saving the CAD Drawing in CAD, change the value of Decimal places of accuracy to 3.

 