Users Main

User FAQ

Bulletins

Online Support

Home

 

 

 BUILD MASTER

 

 SUPPORT LINKS :::

  Installation

  Input Plan

  Edit Plan Data

  Drawings

  Analysis

  RCC Beam Design

  RCC Slab Design

  RCC Column Design

  RCC Footing Design

  Quantity Estimation

  Miscellaneous

  Inside Build-Master Bullentins

 

 

SOLUTIONS :::

 


IN-TR-01. Message displayed "Lock not Installed".
Solution: While running the software, if the Lock is not detected properly a message is displayed on the screen 'Lock not installed on Machine'. Check whether the Hardware Lock is connected properly as per the instructions described in IN-FQ-02

IN-TR-02. Message displayed "Unknown Error".
Solution: If the Hardware Lock is not installed ,'Unknown Error' message is displayed after running the software. Install the USB or Parallel Port Lock driver as mentioned in IN-FQ-02.

IN-TR-03. Message displayed "Debug Assertion Failed".
Solution: If the Active-X components are not registered properly while installing the software a error will be displayed 'Debug Assertion Failed' on the screen while executing various commands of Build-Master which are as follows:
1. Random Mesh command in the mesh data dialog box while drawing a mesh.
2. The ModifyARC / ModifyRCC menus in the Edit Plan Data option of Floor menu.
In this case run the Register Active-X Components as explained in IN-FQ-03

IN-TR-04. Message displayed "Unable to Initialize DAO/Jet Engine".
Solution: 'Unable to Initialize DAO/Jet db engine' message is displayed on the screen if the Dao/jet engine is not initialized properly. Install the MS ACCESS DAO/ Jet Engine as explained in IN-FQ-04

IN-TR-05. Message displayed "Failed to create Empty document".
Solution: 'Failed to Create Empty Document' error message will be displayed on the screen if the program is unable to create a new database file. Install the MS ACCESS DAO/ Jet Engine as explained in IN-FQ-04

IN-TR-06. Main Menu Screen doesn't appear.
Solution: The main menu screen of Build-Master doesn't appears after the title screen If this happens Press Ctrl + Alt + Del only once. The Close Program dialog box will then appear on the screen. Now Select Build-Master.Exe Name and Click on End Task. Check whether the lock is properly installed or not.

IN-TR-07. Message displayed "Error during the Move Data Process:115".
Reason: Sentry files are read only in windows folder.
Solution:
Go to C:\ Windows from Explorer
1) Arrange the files by ‘Name’
2) Look for the file names starting with ‘sentry’ from the list of files.
3) Select all sentry files & right click in the blue area.
4) Select ‘Properties’ option.
5) A dialog box appears Undo tick to remove Read attribute & click OK.
6) Again Run setup.exe program

IN-TR-08. Message displayed "Error 623".
Reason: Earlier Installation command was run halfway.
Solution : Delete the Build-Master folder & reinstall.

IN-TR-09. Message displayed "Cannot Run 16 Bit Application".
Reason: Problem in your WINDOWS XP Installation.
Solution: Contact your Hardware Vendor.

 

BACK | TOP

If you still have unanswered questions after browsing the material, please let us know about it by emailing us at:
support@ensoftindia.com

 

 

 

 Email

 

Copyright ENSOFT INDIA. Site best viewed in 1024x768 resolution.